32.0MMBTU/H AERIAL COOLERS (2)

Never Used
39-01-0010

32.0MMBTU/H AERIAL COOLERS (2)
Built in 2008 and never put into service

Titanium Section
Duty: 10MMBTU/H
Design Pressure: 300 PSIG @ 400° F
Bare Surface Area: 1,333 Ft.²
Extended Surface Area: 28,024 Ft.²
Tubes: 129 x 1" OD x 40' L
Tube Material: SB-265-12-1253400
Inlet: 3" 300
Outlet: 3" 300
316L Stainless Steel Section
Duty: 22MMBTU/H
Design Pressure: 300 PSIG @ 400° F
Bare Surface Area: 2,200 Ft.²
Extended Surface Area: 46,273 Ft.²
Tubes: 213 x 1" OD x 40' L
Tube Material: SB-463-N08020 / SA-240-316L
Inlet: 20" 300 RFWN
Inlet: 8" 300 RFWN
Outlet: 12" 300 RFWN
Outlet 8" 300 RFWN
Steam Coil
Design Pressure: 77 PSIG @ 800° F

Shipping Dimensions: 18' x 20' x 20'H
Never used & stored in Alberta

 
Gallery: 
For more information contact:
Colin Gunning Tel: (587) 231-0122